Site requirements
Operating environment
Relative humidity: 20% to 80% non-condensing
Temperature: 60° F to 95° F (15° C to 35° C)
Electrical requirements
The power supply is rated at 100-240 VAC, 50-60
Hz, 1.8 amp. (It adjusts to any power within this
range.)
Single phase, 3-wire, grounded receptacle only.
Physical requirements
The printer weighs less than 11.5 pounds (5.3 kg).
The weight depends on the supplies and options
installed.
Printer dimensions are 21.5 inches (546 mm) long, and 7.8 inches (198 mm) wide. The 100-card input hopper
is 9.5 inches (241 mm) high and the 200-card hopper is 11.9 inches (302 mm) high.
The clearances required are 1 inch (25 mm) at the back, 2 inches (51 mm) on the left side, and 10.5 inches
(267 mm) above the printer latch to open the cover.