Maxsys and MX Series Software Administrator’s Guide 141
4. Select the Item Id. Assign an Item Id number for the insert, and then select
OK at the bottom of the dialog.
For example, the insert with Item Id 2 can be assigned to Hopper 1; Item Id
3 can be assigned to Hopper 2; and so forth. The default Item Id for normal
operation (non-Selective Inserts) is Auto.
5. In the same hopper dialog box, select the Feed Control Mode value to edit it.
In the Feed Control Mode dialog box, select Barcode select.
6. Select OK to save.
The typical Feed Control Mode value is Feed always. However, for these
inserts you must use the Barcode select value.